Schenck Intecont Plus Manual As recognized, adventure as skillfully as experience approximately lesson, amusement, as skillfully as union can be gotten by just checking out a ebook schenck intecont plus manual next it is not directly done, you could admit even more not far off from this life, roughly the world. For schenck process intecont plus, but stop occurring in harmful downloads. Rather than enjoying a good book as soon as a cup of coffee in the afternoon, then again they juggled taking into consideration some harmful virus inside their computer. Operating manual for schenck process.
Intecont Tersus – Free download as PDF File .pdf), Text File .txt) or read for weighing tasks better than % Manual and/or automatic zero setting Full. The INTECONT Tersus weighing elec- tronics is specially tion module, INTECONT Tersus optimally fits into any Manual and/or automatic zero setting. processes, the INTECONT Tersus meas- uring, control, and supervisory module, INTECONT Tersus optimally fits into any Manual and automatic zero setting.
Author: | Akinorg Dojinn |
Country: | Antigua & Barbuda |
Language: | English (Spanish) |
Genre: | Art |
Published (Last): | 6 August 2004 |
Pages: | 369 |
PDF File Size: | 17.43 Mb |
ePub File Size: | 12.46 Mb |
ISBN: | 306-6-33236-182-7 |
Downloads: | 61249 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Gardalabar |
Manual Intecont Tersus
If the optional activation is required on devices which have already been delivered, the intecobt is transferred to the Schenck process, and the generated activation code is reported back. Feeder is no longer operable. The dimension data should be adapted to the Nominal Flow Rate.
Before performing work on the electrical equipment, disconnect the power supply. The full force Q acts on the load cells. The measuring system can be part of a jntecont complex plant. The duration of the impulse is set by P This function is only available in batching mode.
Number of the parameters in the block Explanatory name of the parameters language-dependent Depending on the situation, individual parameters or groups of parameters may be faded out to highlight the parameters important to an application.
Then it shows the new setting for a couple of seconds as Current Time. Belt Skew WM04 Event: The load on the platform exerts a force on the load cell LC through one or more weighing idlers.
The inclination of the belt may only be entered for systems in which the load cells are arranged perpendicular to the belt. The value can be analyzed as per item b. A belt weigher only measures and it cannot influence the feed rate. Password Confirm Defines the access protection for using the operating console.
Any reproduction of this documentation, regardless of method, without prior permission by Schenck Process GmbH in writing, even by excerpt, is prohi-bited. Calibration active is shown in the header. Display filters For feed rate, belt load and belt speed Maintenance guidelines through the appearance of an event in the display For the voltage supply’s operating time, for the scale’s operating time and for the next zero setting. When it reaches the batch setpoint, the conveyor belt and material prefeeder are turned off and the feeding process is ended.
Schenck Intecont Plus Manuals
It makes sense to go through all of the parameters and consider the value entered. There is the danger of injury if persons are in the area of the drives. The measuring system operating company must ensure that the password is handled safely. Bulk solids can be transported and cover the following equipment. Calibration Calibration of the pick-up input is not necessary.
The length ratio from the centerline of the weighing platform to the material dispatch to the overall belt conveyor length is known. The belt speed is adapted by the controller so that the belt load always equals the rated value.
Secure them against inadvertent restart. Schenck intecont plus pdf -? It can be integrated in the control panel or is available with a glass fibre reinforced plastic wall-mounted housing for on-site installation. Some parameters can be write protected. It only shows the functions that can be called up now. Call up tefsus function block Calibration Set Time Abort possible at inhecont time Enter the year, month, day, hour, minute and second.
Apply calibration weight Q1, start the scales and call up the zeroing program.
Analyze any event messages that may appear and rectify the fault. The current value of the P Slip W1 P This manual is available in different forms: Function block Calibration CW: It is determined by the design of the weighing platform and can usually be found in the technical data sheets.
Instead, the measured belt load is used before changing over. The following conversion formula applies to the effective bridge length with single-roll weighbridges: The list of all possible event messages and the current hardware allocation is printed out as an appendix. The effective calibration weight QPRF is the weigh-ing platform load in kg simulated by the calibration weight.
This is why it is normally only possible to guarantee a high level of accuracy over entire belt cir-cuits i. The meas-ured feed rate or actual belt load value is not taken into consideration. Cancel the program and do not exceed the result. Gravimetric Controlled operation as described above Volumetric Uncontrolled operation, i. Damaged or defective electrical components must immediately be re-placed or, if possible, repaired by qualified personnel.
Schenck Intecont Plus User Manual
This is done by loading the weighing plat-form with a known calibration weight and automatically calculating the average platform load over one or several whole belt circuits.
INTECONT® Tersus
The write protection can also be configured using EasyServe. XC1 DeviceNet module front view If noch tacho is active don’t change characteristic value vs. They adapt their font size over 3 levels. Access to some functions can be configured in the Dialog Behaviour block. The product is feed rate I. No entry can be made if batch mode is deselected or if a batch terssus in process.
Related Posts (10)
Schenck Intecont Plus Manual
%
Convenient data management on standard Windows PCs
%
Network-compatible in a server-client database environment
%
Multilingual operator prompting
%
Wagon identification via RFID long range tag reader
%
Fully automatic mode possible
%
Data acquisition and remote control in WLAN using hand-held terminal
%
Flexible connection to user’s EDP systems
(Fig. 1)
Application
Functions
The DISOWARE Terra software is designed as data management system for MULTIRAIL® LegalWeight, MULTIRAIL® LiquidWeight and MULTIRAIL® MultiBridge rail weighbridges of Schenck Process.
DISOWARE Terra comes with a host of functions, processes and options for utilisation of your weigh data. • Control of connected dynamic or static rail weighbridge • Easy acquisition, display, edit, evaluation, export, import, print, delete, and search of weigh data • Flexible evaluation tools for individual configuration of database queries • Master data tables for wagons, suppliers, receivers, material types and comments • User management with multiple access privileges • Data safety through integrated mechanisms for saving and restoring of database • Remote control of weighing operation through user’s EDP-systems
Used for control and direct communication with the connected rail weighbridge, this software lets you process your weigh data with utmost ease and interface any EDP-system available in your plant. The use of an SQL database ensures maximum data safety both with single user systems and in the network of a multi-user environment.
• •
•
• •
•
•
BV-D2216GB
Fully automatic mode with no need for operator intervention Integrated wagon identification with the use of RFID-tags and appertaining long range tag reader system (<10 m reach) Integrated wagon monitoring system for evaluation of wheel and axle loads using defined limit values Remote maintenance and update options for complete software Automatic recognition of first and second weighing with subsequent NET weight computation Data acquisition and remote control of scale in WLAN using rugged industrial hand-held terminal Empty-state check weighing with automatic update of TARE weight in wagon master file
Weighing Mode Fig. 1 depicts the DISOWARE Terra main window that readies all functions required for easy handling of connected scale and acquired weigh data. • Convenient acquisition of train data complete with • Wagon number, including check number check • Material, supplier, receiver, comments • Up to 3 containers with declared tare • Order, shipper and track numbers, NHM code • Input of first, second or tare weighing for each single wagon •
•
Acquired weight is stored in wagon file complete with data, so that empty weight can be checked
DISOWARE Terra Modules The functions of the various modules partially depends on available hardware. •
Convenient editing of acquired train lists: • Wagon arrangement, weighing mode and all assigned data • Train explorer (Fig. 2) for convenient assembly of new train from existing data by mouse click
During weighing, the wagon monitoring function checks speed, highest wagon axle load, wagon side and front/rear ratios using defined limit values. Any excess is output on report monitor, reported via digital output and can be printed in form of an error report (Fig. 3). Weigh data are assigned to acquired train data, so that load limit can be checked for compliance with limit value from wagon file, reported and printed.
(Fig. 3) •
The wagon identification function comprises one or multiple long range RFID-tag reader system(s) and a semi-passive tag attached to every wagon (see Fig. 4). Using the ID stored in the RFID-tag wagon data are read from master data, train is automatically formed, and train list with wagon number is printed and stored.
(Fig 2) •
Fast-track acquisition function for trains with wagons containing same load for same receiver
•
Dynamic and static weighing control functions; data acquisition possible during weighing
•
Train weighing before acquisition of train data. Acquired train data can be assigned also after weighing
•
To save input time, wagons to be left out can be marked after weighing (no data acquired)
•
Trains can be weighed partially and comprised to form a new train at a later time
(Fig. 4) •
The DISPO EDP connection readies an interface based on the exchange of ASCII files. DISOWARE Terra uses supplied file to form the train list that can be completed by the operator. After weighing, software assigns weigh data, prints train list and writes result file.
•
The DEBIS EDP connection enables complete control of scale including feedback of weigh data via serial interface (Fig. 5). The protocol offers freedom of adaption; standard S3964R is also realised. No PC intervention is necessary.
(Fig. 7)
(Fig. 5) •
The MQ Series EDP connection lets you realise a • fully automatic scale. Weighing is started via a rail switch for any direction of travel. When weighing is complete, data are entered into the MQ series message queue and are available for further processing by user. Scale status also enters into message queue in cycles.
•
The SAP R/3 EDP connection can be realised via IDoc standard interface. Wagon arrangement can be adopted from SAP R/3, or weighing results transferred to SAP R/3.
•
EDP connections to Oracle databases with data acquisition and transfer are realised as well.
•
The Evaluation/Export EDP connection readies CSV files in ASCII format using freely definable SQL commands.
•
Mobile data acquisition and remote control of scale can be effected on rail direct, or started by the engine driver via a rugged industrial hand-held terminal (Fig. 6) or commercial PDA. The handheld terminal lets you acquire complete trains and start weighing. A PC can be connected using the cost-effective open WLAN 2.4 GHz or the coordinated frequencies 450 MHz ... 470 MHz. Data can also be acquired in the form of a web application, with inputs being made via Internet Explorer.
The Balance window (Fig. 8) readies functions for preparation of evaluations, e.g. a material throughput statistic for a certain supplier over an optional period of time.
(Fig. 8) •
For convenient acquisition of master data, acquisition screens (Fig. 9) are available for all master data tables. These screens represent single data records in a set form. Compared to table input, these forms are much easier to handle.
(Fig. 9) • (Fig. 6) • The weighing file stores all previously effected weighing operations (Fig. 7). The window prompts for input of period, wagon, customer, material type, supplier and product. These data can be combined • at will, so that simple reports, e.g. by shift or customer, can be displayed and printed.
Backup and Restore For the sake of data safety, a database safety copy should be prepared regularly. To do so, you can use the backup function that lets you save data on a predefined backup medium. In case of data loss, the Restore function lets you return to the state at the time of data saving. The DISOSAVE program lets you store weigh data legal-for-trade (Data Sheet BV-D2045) and is approved for legal-for-trade storage on PC throughout the European Community.
Relevant Data Sheets BV-D2142 BV-D2279 BV-D2221 BV-D2045 BV-D2066 BV-P2050
Special Configurations DISOWARE Terra special configurations can be offered at any time, e.g. - Connection to your EDP system - Adaption to existing processes
Please let us know your requirements, we will gladly provide you with a tailored solution.
Schenck Process GmbH Pallaswiesenstr. 100 64293 Darmstadt, Germany Phone: +49 6151 1531-3431 Fax: +49 6151 1531-1043
[email protected] www.schenckprocess.com
BV-D2216GB 1135 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2011
MULTIRAIL LegalWeight MULTIRAIL LiquidWeight MULTIRAIL MultiBridge DISOSAVE Legal-for-trade Memory DISOVIEW E L-f-t Scale Window Clearing the way for greater safety