The R7044 Excel Plus Controller ('R7044') is one of a family of Processors used in EXCEL 5000� System. R7044s can operate in stand-alone mode. They can also operate as an integral part of a peer communications network sharing data with other Tier 2 processors or with a host central processor.
- Honeywell Model K10145 Manual
- Honeywell R7044
- Honeywell R7044 Manual Pdf
- Honeywell Setup Manual
- Honeywell R7044 Manual Instructions
Honeywell Building Controls Commercial HVAC Solutions. CNI - C-NAP Network Interface is the board that is installed in the R7044 D, E or G and will run the subsystem bus for this interface. Interfaced subsystem/subsystem - shall refer to the Tek-Air controllers that are connected to the CNI board via the RS485 bus. R7044 - is also known as the HPEP (High Performance Excel Plus) controller. CNI - C-NAP Network Interface is the board that is installed in the R7044 D, E or G and will run the subsystem bus for this interface. Interfaced subsystem/subsystem - shall refer to the Tek-Air controllers that are connected to the CNI board via the RS485 bus. R7044 - is also known as the HPEP (High Performance Excel Plus) controller. Honeywell R7044 Manual If you are searching for the ebook Honeywell R7044 Manual in pdf format, in that case you come onto the right website. We present the utter variation of this ebook in txt, DjVu, ePub, PDF, doc forms. You can read Honeywell R7044 Manual online or download.
The various R7044 models provide different configurations of analog, digital, totalizer, and universal points. Universal points are primarily analog outputs; however, they can be used as digital outputs, or, on Models D and E they can be digital/analog inputs.
To complement stand-alone operation, a W1044 Excel Plus Operator Terminal ('P.O.T.') is available. This hand-held or door-mounted operator interface provides direct access to and command of point data and stored operating parameters. An optional Control Network Automation Protocol (C-NAP) Network Interface board provides an interface between R7044 Models D, E, and G and MicroCel� and/or MacroCel� Controllers. Models D, E, and G also support optional 'flash' memory and an optional autodial modem for dialup to a Tier 3 central processor.
� Stand-alone energy management and direct digital control
� Flexible input/output configuration
� Point density optimized for distributed processing
� Fully compatible with higher-order host systems
� Battery-backed real-time clock and RAM (Models A and B)
� Capacitor-backed real-time clock and RAM (Models D, E, G)
� W1044 P.O.T. port
� Processor active and diagnostic LEDs
� Installable and serviceable packaging
� Digital output LED indicators and HAND-OFF-AUTO switches
� Optional C-NAP Network Interface (Models D, E, G)
� Optional dialup to higher-order processor (Models D, E, G)
� Optional flash memory (Models D, E, G)
DESCRIPTION
R7044 Excel Plus Controllers ('R7044s') perform analog and digital point processing for sensors and actuators as well as local Direct Digital Control (DDC), Energy Management System (EMS), and system control functions. R7044s can operate in either stand-alone configuration or as Tier 2 processors in a peer communication network sharing data with other processors. With an optional Control Network Automation Protocol (C-NAP) Network Interface, MicroCel� and/or MacroCel� Controller points look like sensors and actuators that R7044D, E, and Gs can monitor and supervise or reset.
The Flash Memory Board option for R7044D, E, Gs permits reprogramming nonvolatile operating system (OS) and data file memory without having to physically remove and replace any memory devices. Reprogramming can be from the Excel Building Supervisor Integrated operator interface or W1045 Excel Plus Portable Programming Terminal ('W1045 PPT') via hardwired or dialup communication lines.
R7044A-E, G Software Specification Data Sheet 74-2373, and Excel Plus Dialup Specification Data Sheet 74-5814 provide further details on R7044 functionality.
SPECIFICATIONS
Models:
- R7044A Excel Plus 34-Point Controller
- R7044B Excel Plus 66-Point Controller (includes I/O Expansion Board)
- R7044C I/O Expansion Board Only
- R7044D Excel Plus 40-Point Controller (48 points with optional Analog Output Expansion Board)
- R7044E Excel Plus 64-Point Controller (72 points with optional Analog Output Expansion Board)
- R7044G Excel Plus 4-Point Controller (totalizer inputs only)
Physical Characteristics:
Environmental Limits:
Operating Temperature: 32 to 122F (0 to 50C)
Storage Temperature: �40 to 158F (�40 to 70C)
Humidity: 5 to 95% rh max noncondensing
Electrical:
Models A and B:
24V ac +10%, �15%, 50/60 Hz ±1 Hz, 3.5A (includes W1044 Excel Plus Operator Terminal [P.O.T.], I/O Expansion board, and 16 relays)
24V dc +20%, �15%
Models D, E, and G:
120V ac +10%, �15%, 47-63 Hz, 0.59A
220V ac +10%, �15%, 47-63 Hz, 0.30A (includes W1044 P.O.T. and 20 relays with 24V coils at 40 mA)
Mounting:
R7044A-E: On subpanel in full-size ring cabinet or in a steel housing
R7044G: On subpanel in half-size ring cabinet
Accessory mounting space available in full-size ring cabinet
Removable terminal strips for trouble-free installation and serviceability (Models A and B)
Barrier terminal strips for easy wiring installation (Models D, E, G)
Internal static and transient protection
Optional C-NAP Network Interface (CNI) Board: field-installable daughterboard
Optional Flash Memory Board: field-installable daughterboard. The board fits on either a panel- or enclosure-mounted R7044. The Flash Memory Board can coexist with the CNI Board but not with the Analog Output Expansion Board. There is a Flash Memory Board version that includes analog output expansion features. See Optional Flash Memory Board item later in the specification sheet for version number.
Optional Analog Output Expansion Board: field-installable daughterboard. The board fits on either a panel- or enclosure-mounted R7044. The board can coexist with the CNI Board but not with the Flash Memory Board.
Enclosures:
Models A-E:
Full-size ring cabinet: 37-1/4 in. (947 mm) high, 24 in. (610 mm) wide, 9 in. (229 mm) deep
Model G:
Half-size ring cabinet: 18-5/8 in. (473 mm) high, 24 in. (610 mm) wide, 9 in. (229 mm) deep
Communication:
Ac-coupled, peer communication (RS-485) bus
RS-232-C serial communication port
Maximum Number of R7044s on a Peer Bus: 29
Input/Output Point Capacity:
R7044A: 32 points and 2 totalizer inputs
16 analog/digital inputs
8 analog outputs
8 digital outputs
R7044B (with I/O Expansion Board): 64 points and 2 totalizer inputs
32 analog/digital inputs
16 analog outputs
16 digital outputs
R7044C: I/O Expansion Board Kit to convert Model A to Model B
R7044D: 36 (optional 44) points and 4 totalizer inputs
18 analog/digital inputs
6 universal analog/digital inputs/outputs
12 digital outputs
Optional 8 analog outputs* (with Analog Output Expansion Board)
R7044E: 60 (optional 68) points and 4 totalizer inputs
30 analog/digital inputs
10 universal analog/digital inputs/outputs
20 digital outputs
Optional 8 analog outputs* (with Analog Output Expansion Board)
R7044G: 4 totalizer inputs
*These outputs can also be used as maintained digital outputs.
Input/Output Point Characteristics:
Analog Inputs�Analog inputs support voltage ranges of 0 to 10V dc, and a resistance type input range of up to 8000 ohms for R7044A, B and 5.5K ohms for R7044D, E. Analog inputs can be used as totalizer inputs with 4 to 20 mA signal at a 2-second minimum scan rate.
Sensors supported: Balco, 3000- and 1000-ohm platinum, and PT100 (two-wire mode).
Analog Outputs�Linear voltage range of 2 to 10V dc with maximum current of 20 mA. Output signal 0 to 12V. Can be used as maintained digital outputs. Data file defines usage.
Digital Inputs�Voltage level, current level, and contact inputs with a minimum of 1-second hold.
Digital Outputs�Maintained or pulsed with pulse duration from 100 ms to 2.5 seconds, programmable in 100-ms increments. Maximum maintained current is 50 mA per output. Four- and eight-relay board assemblies support a number of relays with different contact ratings. The four-relay boards have LEDs to indicate if coils are energized and optional HAND-OFF-AUTO switches.
Start/Stop types supported: maintained, universal, momentary, two-speed motors, and 12V/24V magnetic latch.
Totalizer Inputs�Pulse type with frequency of up to 20 pulses per second. Minimum contact opening or closing time is 21 ms.
Microprocessor:
MC68000
Data File:
EPROM for Operating System (OS). With optional flash memory, data file and OS resides in nonvolatile Flash EPROM.
Battery-backed RAM for DDC/EMS parameters (modifiable via W1045 PPT and central operator interface when R7044 is connected to a host processor). With optional flash memory, parameter changes can reside in nonvolatile Flash EPROM.
Memory Capacity:
Models A and B:
Honeywell Model K10145 Manual
RAM 32 kilobytes (KB) nonbattery-backed, 32K bytes battery-backed
OS EPROM 256KB
Data File EPROM 64KB
Models D, E, G:
RAM 256KB capacitor-backed
OS EPROM 512KB
Data File EPROM 64KB (expandable to 128KB on main board)
Optional CNI Board provides the following additional memory capacity:
RAM 64KB to 256KB
Data File EPROM 128KB
Optional Flash Memory Board provides:
OS Flash EPROM 512KB
Data File Flash EPROM 256KB
SCRAM (SRAM) 256KB
Backup:
Models A and B:
72-hour battery-backed RAM
Nonrechargeable lithium battery
Models D, E, G:
8-hour capacitor-backed RAM
72 hours with addition of optional nonrechargeable lithium battery
With optional Flash Memory Board, user changes can reside in nonvolatile memory and remain unchanged over any length power interruption
Transmission Rate:
9600 bits per second
Accessories:
NEU-DK-16 Matrix Board (8x2) for up to 16 digital input points
NEU-DK-64 Matrix Board (8x8) for up to 64 digital input points
14506635 Rough-in Ring Cabinet
14006090-028101 Full-size Door with P.O.T.
MCRSM2400 or MUSMT224EH7 (for UL systems) autodial modem for R7044D, E, G
14502654-003 modem cable, 5 ft (1.5m)
14506921-001 modem bracket
Optional C-NAP Network Interface Board (R7044D, E, G Only):
Ordering: 14506839 C-NAP Network Interface board
Board Dimensions: 5 in. (127 mm) x 12 in. (305 mm)
Installation: Field-installable daughterboard
Interface: 198 (maximum total) Excel MicroCel and/or MacroCel Controllers of which 12 can be MacroCel Controllers, 5000 (maximum) MicroCel/MacroCel points (analog inputs and outputs, digital inputs and outputs, and pseudopoints) mapped to R7044 points during system engineering
Approvals: Underwriters Laboratories Listed per UL Standards 864 and 916; complies with FCC Part 15
Optional Flash Memory Board (R7044D, E, G Only):
Ordering: 14507140-001 Flash Memory Board with analog output expansion (same features as separate Analog Output Expansion Board)
Honeywell R7044
14507140-002 Flash Memory Board without analog output expansion
NOTE: The Analog Output Expansion Board cannot coexist with a Flash Memory Board. Use 14507140-001 to get both features.
Board Dimensions: 6 in. (153 mm) wide x 11-1/4 in. (29 mm) high
Installation: Field-installable daughterboard (mounts on top of the R7044D, E, G Processor Board)
Features: Surface-mount technology; seven-segment diagnostic LED display; default baud rate switch for loading via modem
Honeywell R7044 Manual Pdf
Approvals: Underwriters Laboratories Listed per UL Standards 864 and 916; complies with FCC Part 15
Optional Analog Output Expansion Board (R7044D, E Only):
Ordering: 14506986-001 Analog Output Expansion Board; mounts as daughterboard on R7044D, E
14506982-001 Analog Output Subpanel Expansion Kit; contains field wiring strip
Approvals:
Underwriters Laboratories Listed per UL Standards 864 and 916 (R7044D, E, G only)
Complies with FCC Part 15
Honeywell Setup Manual
Honeywell Latin American Region Home Building Control Honeywell Europe S.A. Honeywell Asia Pacific Inc. |
74-3882 Rev. 3-94
Honeywell R7044 Manual Instructions
K4461-1V1 8/05 Rev. B
ADEMCO 6150RF
ADEMCO 6150RF
ADEMCO 6150RF
ADEMCO 6150RF
Keypad/Transceiver
Keypad/Transceiver
Keypad/Transceiver
Keypad/Transceiver
USER GUIDE
Keypad Features
DISPLAY
The keypad features a three-digit numeric display for zone identification and pre-designated English-
language prompts (e.g., “ALARM,” “AWAY,” “STAY,” “CHECK,” etc.) for indicating system status. (Refer to
Figure 1.)
FUNCTION KEYS
The function keys are located behind a decorative door and are continuously backlit for ease in use.
(Refer to
the User’s Guide provided with the control panel for detailed instructions on the use of these keys.)
The function keys include keys for panic alarm activation. The panic alarms are activated by pressing key
pairs [1] & [*], [3] & [#], or [*] & [#], or a Special Function Key (see below). Whether these panic keys
function and the type of panic alarms they produce is determined by the control panel’s capability and
programming.
(Check with your installer for the further information regarding these keys.)
SOUNDER
The sounder is a piezo-electric sounder that pulses for fire alarms and generates a two-tone sound for
burglary and audible panic alarms.
KEYPAD LEDS
The keypad contains two LEDs that indicate the status of the system as follows:
LED Function
Green (Ready)
Lights when the system is ready to arm (no zone faults are
present).
Red (Armed)
Lights when the system is armed.
SPECIAL FUNCTION KEYS
These are four keys located to the left of the numeric keys (refer to Figure 1). The keys may be programmed
by your installer for panic alarms or other special functions such as macros (a frequently used series of key
entries).
Function keys must be held down for at least 2 seconds to activate an alarm.
(Check with
your installer for the programmed function of these keys.)
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
6150RF-00-001-V1
Figure 1 - ADEMCO 6150RF Keypad/Transceiver (Front Door Removed)
User Mode
This mode gives you the capability of enabling and disabling individual wireless keys that have been
directly programmed into the ADEMCO 6150RF. This is particularly useful if a user loses a wireless key.
This mode may only be accessed if the ADEMCO 6150RF is powered up for at least 1 minute.
Only
wireless
keys programmed directly into the ADEMCO 6150RF may be enabled and disabled using this mode.
ENTER THE USER MODE
Press the [1] and [3] keys simultaneously for a few seconds (make sure the unit has been powered for at
least 1 minute prior).
CHANGING THE STATUS OF A TRANSMITTER
On the display, “dE” and “-” flashes alternately. Enter the number of the wireless key transmitter (1-8).
Then “d” and the wireless key number you entered flash alternately with “1” or “0” on the display. A “1”
indicates the wireless key is enabled, a “0” indicates it is disabled. Enter [1] to enable or [0] to disable the
wireless key. All wireless keys are defaulted to 1 (enabled).
Press the
[
✻
]
to accept the entry.
Repeat the procedure for all the wireless keys whose status you want to change.
EXITING THE USER MODE
To exit the User mode press
[
✻
]
when “dE” and “–” flash alternately on the display.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or Use
r's Manual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
FCC CLASS B STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statem
ent for
your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance
with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to com
ply with the
limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to prov
ide
reasonable protection against such interference in a residential installation. However, there is no guarantee that interference
will not occur in
a particular installation. If this equipment does cause interference to radio or television reception, which can be determined
by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch ci
rcuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1
) This device
may not cause harmful interference (2) This device must accept any interference received, including interference that may cause
undesired
operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis
aux
conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute inte
rference reçue y
compris les interferences causant une reception indésirable.
ÊK4461-1V1eŠ
K4461-1V1 8/05 Rev. B
2
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2009 Honeywell International Inc.
www.honeywell.com/security